INTEGRATED PROJECT DELIVERY

One partner.
Every project stage.

From feasibility and architectural vision to water engineering, MEP construction, intelligent controls, installation, commissioning and long-term service.

01 / CAPABILITIES

Eight disciplines.
One integrated workflow.

01 / STRATEGY

Feasibility & investment planning

Resource review, business concept, budget framework, target guest capacity and development phasing.

02 / DESIGN

Master planning & specialist design

Spa hotels, hot-spring towns, pools, wellness facilities, water parks, fountains and water landscapes.

03 / WATER

Water treatment & water quality

Geothermal water, hot-spring and swimming pool systems: circulation, filtration, disinfection, heating and monitoring.

04 / CONSTRUCTION

Mechanical & electrical construction

Plant rooms, pipework, pool and spa equipment, sauna and steam infrastructure, coordinated installation.

05 / ENERGY

Geothermal & energy optimisation

Cascade use, water-source heat pumps, heat recovery and appropriate humidity control systems.

06 / SMART

PLC automation & remote monitoring

Pump and valve control, water-quality dosing, temperature and level sensing, alarms, dashboards and optional remote operations.

07 / DELIVERY

Equipment installation & commissioning

Technical coordination, equipment integration, functional testing, handover documentation and operator training planning.

08 / LIFECYCLE

After-sales service & maintenance

Inspection plans, consumables, spare parts, troubleshooting, water-quality checks and operational support subject to contract.

02 / DELIVERY

Design that works in the plant room.

Integrated delivery means the spa concept is coordinated with water chemistry, pipework, filtration, heating, electrical infrastructure, controls and maintenance access before installation begins.

The company profile also describes special water treatment for iron, manganese, fluoride and arsenic, geothermal cascade systems and energy-conscious dehumidification.

Project construction documentation
03 / CONTRACT DELIVERY

Clear handover and service.

Technical documentation

Approved drawings, equipment lists, installation manuals and operating procedures as agreed.

Testing & commissioning

Water, controls, pumps, valves, alarms and integrated operating sequences tested against the agreed scope.

Operator training

Planned handover of routine checks, alarm responses, maintenance and water-quality workflows.

After-sales support

Remote guidance, service visits, parts and warranty terms depend on the signed agreement and destination country.

Complete geothermal technical library - 78 pages

GEOTHERMAL ENGINEERING

From the well to the heat user

Concept sequence: source well → filtration and heat exchange → heat users by temperature level → heat pump where viable → approved reinjection or discharge route.

Resource assessment

Review well logs, test yield, source temperature and water chemistry. Compare seasonal loads for pools, domestic hot water and space heating before sizing plant.

Heat exchange and cascade use

Use a heat exchanger to separate source and building circuits where appropriate. Allocate higher-temperature heat first, then evaluate pool heating, low-temperature networks or heat pumps for the remaining heat.

Water treatment and reinjection

Review scaling, corrosion, suspended solids and water chemistry. Select filtration, cleaning and monitoring provisions, and assess reinjection capacity and water compatibility separately from bathing-water treatment.

Medium-deep and hot dry rock

The company profile includes geothermal well drilling and completion, reservoir stimulation and enhanced geothermal systems (EGS). Feasibility depends on the reservoir, drilling data, injection response and local approvals.

Controls and commissioning

Specify temperature, flow, pressure and energy metering. Agree alarm thresholds, interlocks and fallback sequences. Commission under representative loads and record the operating baseline.

Design and handover drawings

Typical deliverables include a heat and mass balance, process flow diagram, P&ID, plant layout, equipment schedule, electrical single-line diagram, control narrative, test records and as-built drawings as agreed.

View geothermal and heat pump drawings

Engineering for indoor pools and hot springs

Liquid-desiccant dehumidification

A circulating solution absorbs moisture from the incoming air. A regeneration stage removes that moisture and restores the solution concentration for reuse.

Stratified air distribution

Side-mounted outlets serve the occupied zone while high-level exhaust removes warm, humid air. Airflow and condensation control are assessed for each venue.

Pool and geothermal water treatment

System selection begins with source-water testing, anticipated bather load and local requirements. Design can cover circulation, filtration, disinfection, commissioning and maintenance planning.

TECHNICAL PARTNERSHIPS

Private pools, hot springs and water parks

Yuanwang brings experience in planning and engineering large-scale hot spring resorts and water parks. We’re interested in working with specialist teams with technical expertise in high-end private swimming pools.

We’re open to exchanging technical expertise, developing designs together and collaborating on projects that draw on both teams’ strengths.

SOURCE DRAWINGS / 14 PLATES

Engineering drawings and equipment

Reference plates from the Yuanwang group product manual. Open a system and select a plate for the original drawing or layout at a larger size.

Geothermal & building services 5 plates

Heat recovery, heat pumps and humidity control shown in the company’s engineering material.

Cascade heat-use flow
Cascade heat-use flow · Page 69
Cascade system schematic
Cascade system schematic · Page 71
Water-source heat pump schematic
Water-source heat pump schematic · Page 73
Solution dehumidification heat pump
Solution dehumidification heat pump · Page 77
Cascade and dehumidification monitoring
Cascade and dehumidification monitoring · Page 94
Pool and room controls 5 plates

Control architecture for indoor pools, outdoor pools, private guest suites and thermal rooms.

Control architecture and components
Control architecture and components · Page 92
Indoor pool monitoring
Indoor pool monitoring · Page 96
Outdoor pool monitoring
Outdoor pool monitoring · Page 97
Guest-suite pool monitoring
Guest-suite pool monitoring · Page 98
Sauna temperature management
Sauna temperature management · Page 99
Water and light installations 4 plates

Plan layouts, equipment arrangement, a vertical rain module and factory documentation.

Shared hydrotherapy pool plan
Shared hydrotherapy pool plan · Page 82
Light and hydrotherapy layout
Light and hydrotherapy layout · Page 83
Rain module and integrated control
Rain module and integrated control · Page 87
Control factory photographs
Control factory photographs · Page 88